This is an original Porter Cable replacement part manufactured for use with drills. The switch opens the circuit that sends electricity to the motor. Over time switches can wear out and need to be replaced. A symptom of a faulty switch is trouble starting, then running normally once it gets started. This switch is sold individually.

Troubleshooting

This part works with the following brands:
  • Porter Cable
This part works with the following products:
  • Cordless Drill
  • Hammer Drill
Part# 90544100 replaces these:
90544100,

Questions & Answers

?

Our customer Service team is at the ready daily to answer your part and product questions.

Be the first to ask our experts a question about this part!

Ask our Team

We have a dedicated staff with decades of collective experience in helping customers just like you purchase parts to repair their products.

Does this fit my product?

Customer Repair Instructions

All our customer repair instructions are solicited directly from other customers just like you who have purchased and replaced this exact part.

Easy 

30 - 60 mins 

(1 rated repair) ?
  • 1
Sort by:  
Sorry, we couldn't find any existing installation instruction that matched.

Hammer Drill had the brushes and switch fail.

Brian from Downs, Illinois

0 of 1 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Parts Used:
90544100, 637916-04
Remove screws from housing assembly and remove one side, note how the coil spring is placed in the housing. Remove one wire at a time from the old switch and place it in the same place in the new switch. Remove worn brushes by pulling back brush retaining spring out of brush holder and placing it on the brush holder terminal. Remove worn brushes and install the new ones. Replace the spring. Put housing back together. Done.