Part Location Diagram of G080270 Generac Fuel Shut-Off Valve
See part A-12 in the diagram
( Grid squares measure 1x1 inch )

Fuel Shut-Off Valve G080270

Manufactured by:
Generac
ERP Number:
ERP11923823
Part Number:
G080270
Original Equipment Manufacturer ?
In Stock
Delivers in 3-5 Business Days!

Easy 

15 - 30 mins 

(22 rated repairs) ?

Does this part fit my model?

Need help finding your model number?

Frequently Purchased Together

?

Troubleshooting

This part works with the following brands:
  • Generac
  • Craftsman
This part works with the following products:
  • Generator
Part# G080270 replaces these:
78298,

Customer Part Reviews

?
4.8
Average Rating (out of 5):
★★★★★
★★★★★
(5 Reviews)
Click to filter by ratings:
  • 5 stars
    4
  • 4 stars
    1
  • 3 stars
    0
  • 2 stars
    0
  • 1 star
    0
  • 1
Sort by:  
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.

Questions & Answers

?

Our customer Service team is at the ready daily to answer your part and product questions.

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Ask our Team

We have a dedicated staff with decades of collective experience in helping customers just like you purchase parts to repair their products.

Does this fit my product?

Customer Repair Instructions

All our customer repair instructions are solicited directly from other customers just like you who have purchased and replaced this exact part.

Easy 

15 - 30 mins 

(22 rated repairs) ?
  • 1
  • 2
  • 3
Sort by:  
Sorry, we couldn't find any existing installation instruction that matched.

Replacing the fuel valve and tank bushing

Don from NEW BRAUNFELS, Texas

17 of 17 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Parts Used:
G080270, G078299
Simple job. Removed fuel cut off valve and bushing after completely emptying the gas from the tank. Inserted new bushing into tank and pressed the new cut off valve into the bushing. Installed fuel line to the valve. Installed securing clip with a pair of pliers. Can\'t beat the price.
Did you find this story helpful?
Thank you for voting!

The bushing was old and had cracked and the valve was old and hard to turn.

DON from SPOKANE, Washington

13 of 13 people found this instruction helpful.
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Parts Used:
G080270, G078299
The bushing and valve assembly seemed to be a little too large to assemble in the existing tank hole. After damaging one bushing trying to install even using some lubricant, I ordered another bushing and drilled the tank hole out just a small amount and then the unit went together fine. Still a very tight fit. I then installed the valve and the fuel line.
Did you find this story helpful?
Thank you for voting!

Grommet was bad on petcock for fuel line.

Christine from DELTONA, Florida

6 of 6 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Parts Used:
G080270, G078299
Drained the fuel from the tank
Removed the fuel line from the valve
Removed the old valve and the old tank bushing
Put a little oil on the new bushing and inserted it into the tank
Put a little oil on the valve and inserted it into the bushing
Installed the fuel line on the valve
Did you find this story helpful?
Thank you for voting!

Repair of gas tank leak.

William from Mayo, Maryland

6 of 6 people found this instruction helpful.
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers
Parts Used:
G080270, G078299
Insert bushing into tank. Insert valve into the bushing. Reattach the gas line to the valve.
The repair worked well and solved the problem
Special thanks for your supplying the needed parts.
Did you find this story helpful?
Thank you for voting!

Shutoff valve leaked, and gasket leaked

RUSSELL from ORLANDO, Florida

3 of 3 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Parts Used:
G085652, G080270, G078299
1. Remove hose from shutoff valve
2. Remove remnants of bushing & shutoff valve
3. Push new the bushing into tank
4. Lube inside of bushing with a very small amount of oil.
5. Push shutoff valve into the bushing until it snaps into place. This is easiest to do if tank has been removed, but it is not necessary if you have small enough hands to work under the gas tank.
6. Loosen all vibration mounts.
7. Lift each corner, remove old mount, replace with new mount, go to next corner until all four are replace. I used a piece of wood to hold up the generator between the frame and generator to remove the vibration mount.
8. Retighten each corner mount, operate generator and check for vibration
Did you find this story helpful?
Thank you for voting!

The valve was leaking gas and the filter was dirty.

Luis from Trujillo Alto, Puerto Rico

2 of 2 people found this instruction helpful.
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Parts Used:
G080270, G078601, G078299
1. I emptied the gas tank.
2. Remove the gas tank to facilitate the valve replacement
3. Remove and install the new valve.
4. Re- Install the gas tank back again.
5. I removed the Air Filter plastic cap, replace the old filter by the new one and install the plastic cap back again.
Did you find this story helpful?
Thank you for voting!

Gas tank valve was leaking.

Luke from Scranton , Pennsylvania

1 person found this instruction helpful.
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Parts Used:
G080270, 0H1411B
Drained the fuel tank. Removed the old valve and retainer washer.
Inserted the new washer into tank than inserted the new valve. That was it.
Did you find this story helpful?
Thank you for voting!

On/off switch was bad , fuel shut off valve and tank grommet was leaking fuel

Vic from FROSTPROOF, Florida

1 person found this instruction helpful.
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
Parts Used:
G080270, G078299, 697854
Removed housing that the on off switch was in depressed the ends of the switch with flat head screwdriver and pushed it out.
Put wires on new switch in proper order and snaplocked back into place.
Tilted unit gas tank to put fuel away from the valve end , removed gas line, pulled and wiggled the gas valve out of grommet.
Pried grommet out of tank with small pry bar, pressed new grommet , pressed valve into grommet
Did you find this story helpful?
Thank you for voting!

the seal and gas shut off valve were old and cracked

john from nicholasville, Kentucky

1 person found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Parts Used:
G080270, G078299
removed the gas line from the gas tank and replaced the seal and valve
Did you find this story helpful?
Thank you for voting!

Carburetor ,fuel system ,tune up ignition.

ALVARO from MIAMI, Florida

1 person found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
Replaced required parts ,decontaminated fuel system .
Did you find this story helpful?
Thank you for voting!
  • 1
  • 2
  • 3

Model Cross Reference

This part works with the following models:
ERP Number: ERP11923823
Manufacturer Part Number: G080270
Brand Model Number Description
Generac 005734 Generator - Portable Generator
Generac 0057351 Generator - 120/240V Portable Generator
Craftsman 131881721 Lawn Mower - Craftsman 42 Inch Power-Propelled Heavy Duty Lawn Mower
Generac 1470-0 Generator - Portable Generator
Generac 3W741B Generator - 4,000 Watt Portable Generator
Generac 3W742 Generator - 5,000 Watt Portable Generator
Generac 3W795B Generator - 4,000 Watt Portable Generator
Generac 3W796W Generator - 5,000 Watt Portable Generator
Generac 3ZC12B Generator - 4,000 Watt Portable Generator
Generac 3ZC12D Generator - 4,000 Watt Portable Generator
Generac 3ZC13C Generator - 5,000 Watt Portable Generator
Generac 4000XL Generator - Portable Generator
Generac 5546-0 Generator - Model # 5546-0 Official Generac Generator
Generac 5557-0 Generator - Model # 5557-0 Official Generac Generator
Generac 5558-0 Generator - Generator
Generac 5561-0 Generator - Model # 5561-0 Official Generac Generator
Craftsman 580327053 Generator - 4,000 Watt Portable Generator
Craftsman 580327054 Generator - 4,000 Watt Portable Generator
Craftsman 580328390 Generator - 8,000 Watt Portable Generator
Craftsman 580676420 Generator - 4200 Watt Portable Generator
Craftsman 580751781 Pressure Washer - 2,500 Psi Pressure Washer
Craftsman 580751782 Pressure Washer - 2,500 Psi Pressure Washer
Generac 7000EXL Generator - Portable AC Generator
Craftsman 75178 Pressure Washer - 2500 Psi High Pressure Washer
Generac 9886-0 Generator - Xl 8,000 Watt Portable Generator, Rev 0
Generac 9898-1 Pressure Washer - Model # 9898-1 Official Generac 7.8-Hp 2500-Psi Pressure Washer
Generac C4000 Generator - 4,000 Watt Portable Generator
Generac C4018 Generator - 4,000 Watt Portable Generator
Generac C4019 Generator - 4,000 Watt Portable Generator
Generac C4020 Generator - 4,000 Watt Portable Generator