Generator 3000005090
- Manufactured by:
- Coleman
- ERP Number:
- ERP12093770
- Part Number:
- 3000005090
Does this part fit my model?
Need help finding your model number?Product Description
?This is an Original Manufacturer Sourced replacement part used on some Coleman Gas Lanterns. Generator includes new gas tip, spring, and tip cleaning wire. If the lantern lights for a few seconds then goes out and there is no sound of air passing through the generator, there is either no pressure in the fuel tank or the generator is clogged.
Frequently Purchased Together
?Troubleshooting
- Coleman
- Lighting
Customer Part Reviews
?- < Prev
- 1
- Next >
Questions & Answers
?Our customer Service team is at the ready daily to answer your part and product questions.
Be the first to ask our experts a question about this part!
Ask our Team
We have a dedicated staff with decades of collective experience in helping customers just like you purchase parts to repair their products.
Customer Repair Instructions
All our customer repair instructions are solicited directly from other customers just like you who have purchased and replaced this exact part.
- < Prev
- 1
- 2
- Next >
The lantern had sat idle with fuel in it for over 10 years
Leslie from Merrit Island, Florida
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Pliers, Wrench set
- Parts Used:
- 3000005090, 242J5201
2. Added solvent and 2 dozen steel BBs and shook (two applications),
3. Replaced Generator.
4. Replaced pressure pump stem and piston.
5. Replaced mantels.
6. Reassembled, added ... Read more fresh fuel, pressurized and fuel tank and lit lantern.
Elements would not light. The generator turn liquid fluid into a pressurized gas.
JAY from CHISAGO CITY, Minnesota
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Wrench set
- Parts Used:
- 3000005090
Hard erratic starting.
Victor from Machesney Park, Illinois
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench set
- Parts Used:
- 3000004344, 3000005090
Globe missing. Generator not working.
Tom from Centre, Alabama
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
- Parts Used:
- 3000005090, 5010000780
2. Removed and replaced generator.
Needed new cap generator and general cleaning
mike from tucson, Arizona
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Wrench set
- Parts Used:
- 2165091, 3000005086, 3000005090, 413D3461, 242J5201
replaced pump cup and replaced generator looking for generator for Coleman 321B and also pump assembly
JOHN from Knoxville, Tennessee
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
- Parts Used:
- 2161091, 3000005090
carefully removed globe and set aside for cleaning with generic glass cleaner
removed old mantels with fingers
cleaned frame with greased lighting
Used small pliers to remove pump cap ring
Pulled pump assembly with fingers, used small screwdriver to pry apart the cup seal ... Read more , replaced with new cup and reassembled with screwdriver and pliers, inspected pump tube with Maglite and found to be relatively clean, reassembled pump into tube and oiled with 3 in 1 oil
installed new Coleman #21 mantels and burned them outside the house, the odor is toxic
replaced fuel cap gasket
Filled fount with filtered Coleman fuel while using plastic Coleman funnel
Carefully pressurized fount with about 40 strokes
used a kitchen match to ignite mantels, first burn always has flames
Used IR thermometer to measure temperature of mixing chamber which was about 500 degrees F
After a 1-2 hour cool down carefully install cleaned globe, install cleaned ventilator, tighten nut with fingers by careful I mean do not touch mantels
Use Nu polish to shine fount and ventilator and shine with old white mean\'s cotton socks
Again re-pressurize with about 5-20 strokes on pump. Lock the pump by rotating clockwise
After a each use of lantern I add 1-2 drops oil through cap oil hole
after about two tanks of fresh fuel, the ventilator reaches 735 degrees F
This lantern has been in my unheated storage building about 20 years.
I light it about once a week
I believe the Model number comes highway 321B
The date impint on bottom of fount is 2 76 which is February 1976
Lantern had not been used in over 25-30 years
john from NORTH BRANCH, Michigan
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench set
- Parts Used:
- 3000005090, 2000026613
2 disassembled the lantern
3. gave everything a good scrubbing and saturated the tank with a rust remover and let it soak
4. drained and rinsed out the tank
5. replaced the generator and installed new mantles
6. new fuel added
7. installed new globe
8. pumped up the tank and ... Read more light the lantern, I will be using the lantern next fall when camping, It was made in the 70\'s and is still in the box it came in from K-Marts
Regulator was stopped up and needed to be replaced
Linda from Washington, North Carolina
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Parts Used:
- 2000032171, 3000005090
Coleman lantern would not stay lit
Patrick from GENESEO, Illinois
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench (Adjustable)
- Parts Used:
- 2421071, 2165091, 3000005090
Coleman lantern generator needed replacement
Glen from Lindsay, Oklahoma
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench set
- Parts Used:
- 3000005090
Replaced the generator
Reinstalled the globe
Lit the lantern to test
Worked great