Part Location Diagram of 903845 DeWALT MOTOR HSG
See part 10 in the diagram
( Grid squares measure 1x1 inch )

MOTOR HSG 903845

Manufactured by:
DeWALT
ERP Number:
ERP18987959
Part Number:
903845
Original Equipment Manufacturer ?
$68.35
In Stock
Delivers in 3-5 Business Days!

Easy 

15 - 30 mins 

(2 rated repairs) ?

Does this part fit my model?

Need help finding your model number?

Product Description

?

This is a genuine item that is supplied by the original equipment manufacturer for use with Porter Cable drywall sanders. It is an identical replacement for a missing or damaged housing that was originally installed on a new unit, please make sure to refer to the appropriate diagrams of your model for the correct location and application of this component. Keep in mind this high-quality item is made of durable plastic and is sold individually.

Troubleshooting

This part works with the following brands:
  • Porter Cable
This part works with the following products:
  • Sander Polisher
Part# 903845 replaces these:
903845, P903845,

Questions & Answers

?

Our customer Service team is at the ready daily to answer your part and product questions.

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Ask our Team

We have a dedicated staff with decades of collective experience in helping customers just like you purchase parts to repair their products.

Does this fit my product?

Customer Repair Instructions

All our customer repair instructions are solicited directly from other customers just like you who have purchased and replaced this exact part.

Easy 

15 - 30 mins 

(2 rated repairs) ?
  • 1
Sort by:  
Sorry, we couldn't find any existing installation instruction that matched.

Housing case cracked

David from Bethlehem, Pennsylvania

0 of 1 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Parts Used:
903845, 78114
Transfer of motor and circuit board to new housing
Did you find this story helpful?
Thank you for voting!

Housing was loose causing motor to rotate.

Robert from Kalamazoo , Michigan

0 of 1 people found this instruction helpful.
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Parts Used:
903845
1. Removed old housing noting the locations of all screws, pc board, switch, motor and drive cable.
2. Placed left half of new housing on main tube with all parts in their proper location, noting the wiring is being protected from pinching and binding.
3. Laid right half of new housing in place and tightened screws to secure a ll components in place.
4. Used a heat gun to remove labels from old housing and transferred to new housing.