Part Location Diagram of GK2400-E Makita Gasket Kit
See part 63 in the diagram
( Grid squares measure 1x1 inch )

Gasket Kit GK2400-E

Manufactured by:
Makita
ERP Number:
ERP11885933
Part Number:
GK2400-E
Original Equipment Manufacturer ?
$45.55
In Stock
Delivers in 3-5 Business Days!

Difficult 

1- 2 hours 

(3 rated repairs) ?

Does this part fit my model?

Need help finding your model number?

Product Description

?

A genuine item that is supplied by the original manufacturer for use with Makita air compressors. This is a high-quality replacement gasket kit which is utilized to provide an air-tight seal between cylinder components, please refer to the appropriate diagrams of your model for the correct location and application of this hardware. Keep in mind the set includes four durable composite material gaskets that are also available individually.

Troubleshooting

This part works with the following brands:
  • Makita
This part works with the following products:
  • Compressor
Part# GK2400-E replaces these:
GK2400E,

Questions & Answers

?

Our customer Service team is at the ready daily to answer your part and product questions.

Be the first to ask our experts a question about this part!

Ask our Team

We have a dedicated staff with decades of collective experience in helping customers just like you purchase parts to repair their products.

Does this fit my product?

Customer Repair Instructions

All our customer repair instructions are solicited directly from other customers just like you who have purchased and replaced this exact part.

Difficult 

1- 2 hours 

(3 rated repairs) ?
  • 1
Sort by:  
Sorry, we couldn't find any existing installation instruction that matched.

would not build pressure

charles from n. chili, New York

0 of 1 people found this instruction helpful.
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Socket set
Parts Used:
GK2400-E
removed compressor and motor assy. from frame. R & R head and replaced gaskets.Also adjusted pressure switch
Did you find this story helpful?
Thank you for voting!

Would not build pressure above 50lbs ran continuously

Craig from Lynnwood, Washington

0 of 1 people found this instruction helpful.
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Parts Used:
GK2400-E
1. Removed connectorto air tanks
2. Removed 4 bolts holding motor in.
3. Slid motor out far enough to get to allen screws holding plastic cover.
4. Removed motor as far as cord would allow.
5. Removed head and gasket, make note of orientation
6. Removed valve plate and gasket, make not of orientation.
7 . Removed 3rd gasket
8. Cleaned gasket material with gasket remover and steel wool pad.
Reverse procedure installing new gaskets.
Compressor holding 130lbs for 3 days no leaks or constant running, fixed 100%

Did you find this story helpful?
Thank you for voting!

would build pressure but not shut off

charles from n. chili, New York

0 of 1 people found this instruction helpful.
Difficulty Level:
Very Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Socket set, Wrench set
Parts Used:
GK2400-E, 171006-E, 211001-E
Removed head from compressor and replaced gaskets. Repaired valve
Did you find this story helpful?
Thank you for voting!