Part Location Diagram of 246428 Graco Pump
See part A-41 in the diagram
( Grid squares measure 1x1 inch )

Pump 246428

Manufactured by:
Graco
ERP Number:
ERP10161597
Part Number:
246428
Original Equipment Manufacturer ?
$506.26
Special Order

Easy 

15 - 30 mins 

(1 rated repair) ?

Does this part fit my model?

Need help finding your model number?

Troubleshooting

This part works with the following brands:
  • Graco
This part works with the following products:
  • Sprayer

Questions & Answers

?

Our customer Service team is at the ready daily to answer your part and product questions.

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Ask our Team

We have a dedicated staff with decades of collective experience in helping customers just like you purchase parts to repair their products.

Does this fit my product?

Customer Repair Instructions

All our customer repair instructions are solicited directly from other customers just like you who have purchased and replaced this exact part.

Easy 

15 - 30 mins 

(1 rated repair) ?
  • 1
Sort by:  
Sorry, we couldn't find any existing installation instruction that matched.

My Ultra 395 lost all pressure when I tried spraying a gritty coating of waterproofing paint.

Robert from Pittsburg, California

3 of 3 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Wrench (Adjustable)
Parts Used:
246428
Remove the inlet hose from pump. Unscrew the plastic cover from the pump throat area to access pump pin. Use a screwdriver to carefully remove round spring holding pin in place, and drive pin out.
Use a screwdriver and hammer to loosen the locking ring holding pump to machine body. Now unscrew the pump from the housing. Simply rever se the procedure to install the new one.
NOTE: Before you install the new pump, run the motor and observe the lowest point of the cam- mark with tape on the housing as a reference. You do not want to screw in new pump too far or the cam will bottom out on the top of the pump housing. screw the new pump in to about 1/4\" below that lowest point, that way you get the longest stroke with the pump. Made mine work better than new in my opinion...

Also- make sure the hose from the pump to the prime/spray valve, along with the valve openings in the filter housing, are clean, and not clogged or it will not build pressure. Takes just a few minutes but will save frustration.