( Grid squares measure 1x1 inch )

Large Double Rocker Switch 511741

Manufactured by:
DeLonghi
ERP Number:
ERP10310270
Part Number:
511741
Original Equipment Manufacturer ?
  Works with your model  5307!
On Order

Easy 

15 - 30 mins 

(27 rated repairs) ?
  Works with your model   5307!

Product Description

?

This authentic replacement rocker switch is supplied directly from original manufacturer. It is specially made for use with DeLonghi heaters. It controls the on/off functions of a unit. Switches are commonly replaced parts, over time, mechanical internals will wear out requiring replacement. This plastic switch is sold individually. To complete this repair you will need a screwdriver. • First make sure the tools is not plugged in • Then you want to remove the cover screws • Remove the old switch • Secure the new switch in place • Reassemble and test the unit

Frequently Purchased Together

?

Troubleshooting

This part works with the following brands:
  • DeLonghi
This part works with the following products:
  • Heater

Customer Part Reviews

?
4.4
Average Rating (out of 5):
★★★★★
★★★★★
(16 Reviews)
Click to filter by ratings:
  • 5 stars
    13
  • 4 stars
    1
  • 3 stars
    0
  • 2 stars
    0
  • 1 star
    2
  • 1
  • 2
Sort by:  
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
  • 1
  • 2

Questions & Answers

?

Our customer Service team is at the ready daily to answer your part and product questions.

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Ask our Team

We have a dedicated staff with decades of collective experience in helping customers just like you purchase parts to repair their products.

Does this fit my product?

Customer Repair Instructions

All our customer repair instructions are solicited directly from other customers just like you who have purchased and replaced this exact part.

Easy 

15 - 30 mins 

(27 rated repairs) ?
  • 1
  • 2
  • 3
Sort by:  
Sorry, we couldn't find any existing installation instruction that matched.

Heater control rocker switch broken.

Henry from Suffolk, Virginia

8 of 8 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Parts Used:
511741
Before disconnecting, I took pictures of the electrical connections with my smart phone. Then it was just a matter of reconnecting the correct wires to the proper terminals and re-installation of the switch and panel holding the switch to the heater.
Did you find this story helpful?
Thank you for voting!

Switch went bad from over heating

James from Winchester , Virginia

4 of 4 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Parts Used:
511741
1. Unplugged heater from wall (low wattage switch still worked)
2. Removed housing.screw inorder to remove housing.
3. Unplugged wires from old switch
4. Removed old switch from housing.
5. Installed new switch in housing
6. Reattached wires in proper order with finger tips
7. Reattach housing
8 . Tighten housing screw
9. Plug heater in wall outlet
10. Turn heater on with new double switch. Works Great
Did you find this story helpful?
Thank you for voting!

Replace switch on deLonge heater

Michael from Portola Valley, California

4 of 4 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Parts Used:
511741
Remove cover, remove switch, replace, reconnect leads
Did you find this story helpful?
Thank you for voting!

Replaced switch

Ed from Berrien Springs, Michigan

3 of 3 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Parts Used:
511741
Unscrew the face and bend the 8 plastic wings in. Remove the front plate. Press down on the clips on the switch and pull out. Disconnect the wires one at a time and put on the new switch. Snap the new switch into the front plate. Snap the front plate into the metal front and screw metal front back on heater. Quick fix.
Did you find this story helpful?
Thank you for voting!

Double rocker switch worn out.

William from Currie, North Carolina

2 of 2 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Parts Used:
511741
Unplugged heater, draw diagram of wiring, remove one screw lift off panel containing
bad switch remove wiring,compress switch locks and remove., install new switch and
replace panel..
Did you find this story helpful?
Thank you for voting!

Wattage power selection switch broke.

Stephen from Harding, Pennsylvania

2 of 2 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Parts Used:
511741
1. Unplugged heater.
2. Removed screw holding cover to heater that had switch mounted on it.
3. Removed wires from old switch that are in pairs of two. The wires stayed in position for re-connection ,
4. Squeezed clips on old switch while pushing it out of cover.
5.Pushed new switch in until clips snapped in place . Replaced wires onto switch.
6.Screwed cover back on. Plugged in and turned on with success.

Ordered my part on day one of a 2 foot snow storm and still got it in 4 days. Thank you.
Did you find this story helpful?
Thank you for voting!

The power swithes were broken from impact.

Craig from Zionsville, Indiana

1 person found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Parts Used:
511741
1: Removed one Phillips head screw from side panel.
2:Pull panel away from unit just far enough to reach cables attached to switch.
3:Gently pull cables off of the switch, keeping them in order for replacement on new switch.
4:Push old switch out of panel from cable side.(may need a little tap)
5:Snap new switch into panel from the front.
6:Reattach cables in the same order they were originally found.
7:Replace panel, catching bottom lip first, and then pushing in the top.
8:Replace screw and your ready to try it out.
Did you find this story helpful?
Thank you for voting!

Original switch became defective.

John from Staten Island, New York

1 person found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Parts Used:
511741
Removed 1/4\" bolt holding control panel in place. Marked location of wires on existing switch. Disconnected wires and removed switch using flat head screwdriver to pry retaining prongs loose. Snapped new switch into position. Re-attached wires in their proper location. Re-attached control panel. Everything worked.
Did you find this story helpful?
Thank you for voting!

Original rocker switch no longer functioned

Robert from RICHMOND, Virginia

1 person found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Parts Used:
511741
Removed the end panel from the heater, took a picture of the wiring scheme on the original switch to make ensure accuracy in installing the new switch, replaced the switch, and then reattached the end panel.
Did you find this story helpful?
Thank you for voting!

Switches had broken off

Jenny from Salinas, California

1 person found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Parts Used:
511741
Removed front piece with screwdriver. Unplugged old switches and replaced with new ones. Placed front piece back on and screwed in place.
Did you find this story helpful?
Thank you for voting!
  • 1
  • 2
  • 3

Model Cross Reference

This part works with the following models:
ERP Number: ERP10310270
Manufacturer Part Number: 511741
Brand Model Number Description
DeLonghi 3107 Heater - Heater
DeLonghi 3107T Heater - Heater
DeLonghi 5108T Heater - Oil Filled Heater
DeLonghi 5307 Heater - Heater
DeLonghi 9308 Heater - Heater
DeLonghi 9608 Heater - Heater
DeLonghi BU24P Miscellaneous - Appliance