Part Location Diagram of 152274-25SV DeWALT Vsr Switch
See part 6 in the diagram
( Grid squares measure 1x1 inch )

Vsr Switch 152274-25SV

Manufactured by:
DeWALT
ERP Number:
ERP10166646
Part Number:
152274-25SV
Original Equipment Manufacturer ?
  Works with your model  DC935!
In Stock
Delivers in 3-5 Business Days!

Easy 

Less than 15 mins 

(2 rated repairs) ?
  Works with your model   DC935!

Product Description

?

This is a Trigger type switch that has 2 terminals, a heat sink, a battery connector and a forward/reverse lever. This genuine DeWalt replacement part is sold individually. Switches are commonly replaced parts in power tools. A switch handles on/off and variable speed functions. They also have a role in electric breaking; they can momentarily reverse electrical polarity. Because switches use mechanical internals, they will degrade and wear out over time, eventually requiring replacement. Some common signs of a broken or failing switch are: • The tool has completely stopped functioning - it will not turn on. • The tool operates intermittently, requiring multiple tries to turn on, until eventually it won't turn on at all. • The variable speed function and electric braking aren't working properly.

Troubleshooting

This part works with the following brands:
  • DeWALT
This part works with the following products:
  • Hammer Drill
  • Cordless Drill

Customer Part Reviews

?
5.0
Average Rating (out of 5):
★★★★★
★★★★★
(1 Review)
Click to filter by ratings:
  • 5 stars
    1
  • 4 stars
    0
  • 3 stars
    0
  • 2 stars
    0
  • 1 star
    0
  • 1
Sort by:  
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.

Questions & Answers

?

Our customer Service team is at the ready daily to answer your part and product questions.

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Ask our Team

We have a dedicated staff with decades of collective experience in helping customers just like you purchase parts to repair their products.

Does this fit my product?

Customer Repair Instructions

All our customer repair instructions are solicited directly from other customers just like you who have purchased and replaced this exact part.

Easy 

Less than 15 mins 

(2 rated repairs) ?
  • 1
Sort by:  
Sorry, we couldn't find any existing installation instruction that matched.

Drill trigger intermittenet

Dennis from Knoxville, Tennessee

1 person found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Parts Used:
152274-25SV
Removed screws from housing after I went and purchased correct torx T-10 screwdriver. Torx bits are too short and will not work. Separated halves and gear assembly. Disconnected wires from trigger switch. Replaced switch reassembled housing replaced and tightened screws. Insert battery and drill away.
Did you find this story helpful?
Thank you for voting!

inoperative switch

Jason from GLOVERSVILLE, New York

0 of 1 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Parts Used:
152274-25SV
removed old switch
inserted new switch
Did you find this story helpful?
Thank you for voting!
  • 1