( Grid squares measure 1x1 inch )

Pressure Switch E108524

Manufactured by:
Husky
ERP Number:
ERP12099628
Part Number:
E108524
Original Equipment Manufacturer ?
  Works with your model  C201H!
In Stock
Delivers in 3-5 Business Days!

Easy 

15 - 30 mins 

(3 rated repairs) ?
  Works with your model   C201H!

Troubleshooting

This part works with the following brands:
  • Husky
This part works with the following products:
  • Compressor
Part# E108524 replaces these:
E108524,

Customer Part Reviews

?
5.0
Average Rating (out of 5):
★★★★★
★★★★★
(4 Reviews)
Click to filter by ratings:
  • 5 stars
    4
  • 4 stars
    0
  • 3 stars
    0
  • 2 stars
    0
  • 1 star
    0
  • 1
Sort by:  
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.

Questions & Answers

?

Our customer Service team is at the ready daily to answer your part and product questions.

Be the first to ask our experts a question about this part!

Ask our Team

We have a dedicated staff with decades of collective experience in helping customers just like you purchase parts to repair their products.

Does this fit my product?

Customer Repair Instructions

All our customer repair instructions are solicited directly from other customers just like you who have purchased and replaced this exact part.

Easy 

15 - 30 mins 

(3 rated repairs) ?
  • 1
Sort by:  
Sorry, we couldn't find any existing installation instruction that matched.

Motor would not stop running

Steve from Milford, Ohio

1 person found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Parts Used:
E108524
1. opened housing
2. disconnect electrical plugs from part (labeled connector pairs to match up properly)
3. remove hose from part
4. Install new part
5. reconnect all connections to new part
6. replaced housing






Did you find this story helpful?
Thank you for voting!

Leaky hose die to corrosion

Michael from WATERFORD, Michigan

0 of 1 people found this instruction helpful.
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Parts Used:
E108524, E106648, E106636
Removed top cover cut old clamps, pulled off old hose before attaching new hose to pressure switch and other fitting, I cleaned other fitting and covered it and end of pressure switch with silicone rubber, attached hose with clamps and let dry 24 hours before filling tank, its been 2 weeks and no leaks so far.
Did you find this story helpful?
Thank you for voting!

compressor stops running before adequate pressure

Johnie from DOUGLASVILLE, Georgia

0 of 1 people found this instruction helpful.
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Parts Used:
E108524
Removed compressor cover
Disconnected pressure hose from old switch
reconnected pressure hose to new switch
swapped electrical connections from old to new
replaced the cover
Did you find this story helpful?
Thank you for voting!