?This is an original replacement part manufactured for use with air compressors. The pressure switch is used to activate the motor when the pressure in the tank drops below the set pressure amount, and to turn off the motor when the pressure in the tank meets the setting. This pressure switch is sold as an individual replacement part.
Troubleshooting
- DeWALT
- Porter Cable
- Compressor
Questions & Answers
?Our customer Service team is at the ready daily to answer your part and product questions.
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Ask our Team
We have a dedicated staff with decades of collective experience in helping customers just like you purchase parts to repair their products.
Customer Repair Instructions
All our customer repair instructions are solicited directly from other customers just like you who have purchased and replaced this exact part.
- < Prev
- 1
- Next >
Compressor would not shut off upon reaching max tank pressure
sumpter from duluth, Georgia
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
- Parts Used:
- 5140062-38
Split compressor module in half by removing deep seated case screws.
Locate pressure switch, and replace with new one.
New switch has working pressure range 20 P.S.I lower than old one. The working pressure range has been lowered by redesign and is stamped on the switch body ... Read more .
Reassemble in reverse order including reconnecting hoses with new clamps
Test unit before permanently remounting in frame chassis unit
If unit shuts down at proper tank pressure, finish reassembly and you are done
Compressor had been damaged in use.
Steven from Snohomish, Washington
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
- Parts Used:
- 5140062-38
Someone had really mistreated this compressor, but it ran very well after the repairs