This is a genuine OEM approved replacement part designed for use with Rolair compressors. The pressure switch is a mechanism which communicates to your compressor when to stop and when to start building up pressure. There are multiple reasons a pressure switch could be leaking air.
To complete this repair you would need: wrench set, nut driver set and a thread-sealing tape.
• Shut off the electricity and drain the air tank
• Remove the tank pressure gauge
• Remove the pressure switch tube
• Remove the pressure regulator assembly
• Disconnect the wires
• Remove the safety valve
• Install the new pressure switch
• Reinstall the safety valve
• Connect the wires
• Reinstall the pressure switch tube
• Screw the pressure gauge onto the new pressure switch and tighten the gauge firmly
• Test the air compressor
- Part Type: Pressure Switch